Manufacturer EATON'S BUSSMANN
Inventory Status In Stock
Ship from China
Transportation method SF Express
制造商零件编号:
NON-25
-
Product change notice - fuse labeling (产品更改通知—标签更改)
NON (250V) 1 ⁄8-600A, General Purpose Fuses
Description: Basic protection 250V NON Class K5 and H general purpose, non-current-limiting, one-time fuses.
Catalog Symbol: NON-(amp)
Ratings:
Volts — 250Vac
— 125Vdc (1⁄8-100A)
Amps — 1⁄8-600A
IR — 50kA Vac RMS Sym. (1⁄8-60A)
— 10kA Vac RMS Sym. (65-600A)
— 50kA Vdc (1⁄8-60A)
— 10kA Vdc (65-100A)
Agency Information:
CE, UL Listed, Class K5 (1⁄8-60A), Std. 248-9,Class H (65-600A), Std. 248-6 (125Vdc 1⁄8-100A),UL Guide JDDZ, File E4274 CSA Certified, Class 1421-01, File 53787 (1⁄8-12A, 65-600A)
†
† For CSA Certified 15-60A, see PON Data Sheet # 4126.
NOS (600Vac) Catalog Numbers (Amps)
NOS-1
NOS-12
NOS-70
NOS-200
NOS-2
NOS-15
NOS-75
NOS-225
NOS-3
NOS-20
NOS-80
NOS-250
NOS-4
NOS-25
NOS-90
NOS-300
NOS-5
NOS-30
NOS-100
NOS-350
NOS-6
NOS-35
NOS-110
NOS-400
NOS-7
NOS-40
NOS-125
NOS-450
NOS-8
NOS-45
NOS-150
NOS-500
NOS-9
NOS-50
NOS-175
NOS-600
NOS-10
NOS-60
Features:
• Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
• NOS one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRON™ LPS-R or ultimate protection Low-Peak™ LPS-RK dual-element, time-delay fuses.
• For general purpose circuits, size at amp rating of circuit
• For motor circuits, size at 300% to 400% according to the NEC® motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
NOS (600V), 1-600A, General Purpose Fuses
Description: Basic protection 600V NOS Class K5 and H general purpose, non-current-limiting, one-time fuses.
Catalog Symbol: NOS-(amp)
Ratings:
Volts — 600Vac
Amps — 1-600A
IR — 50kA Vac RMS Sym. (1-60A)
— 10kA Vac RMS Sym. (70-600A)
Agency Information:
CE, UL Listed, Class K5 (1-60A), Std. 248-9, Class H (70-600A), Std. 248-6, UL Guide JDDZ, File E4273 CSA Certified, Class 1421-01, File 53787
NOS (600Vac) Catalog Numbers (Amps)
NOS-1
NOS-12
NOS-70
NOS-200
NOS-2
NOS-15
NOS-75
NOS-225
NOS-3
NOS-20
NOS-80
NOS-250
NOS-4
NOS-25
NOS-90
NOS-300
NOS-5
NOS-30
NOS-100
NOS-350
NOS-6
NOS-35
NOS-110
NOS-400
NOS-7
NOS-40
NOS-125
NOS-450
NOS-8
NOS-45
NOS-150
NOS-500
NOS-9
NOS-50
NOS-175
NOS-600
NOS-10
NOS-60
For superior electrical protection, Cooper Bussmann recommends upgrading NON (250Vac) and NOS (600Vac) fuse applications to Low-Peak LPN-RK (250Vac) and LPSRK (600Vac) fuses. See page 29.
Features:
• Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
• NOS one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRON™ LPS-R or ultimate protection Low-Peak™ LPS-RK dual-element, time-delay fuses.
• For general purpose circuits, size at amp rating of circuit
• For motor circuits, size at 300% to 400% according to the NEC® motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Contact Us
Mobile: +86 (0) 181 2007 1137
E-mail: jhon@cooper-bussmann.com.cn
http://cooper-bussmann.com.cn/
http://cooper-bussmann.cn/
Don't Have Account?
——————————————————
By creating an account with our online store, you will be able to move through the checkout process faster, store multiple shipping addresses, view and track your orders in your account and more...
——————————————————
We’re pleasure to support you technically requests or sample,pricing questions that you may have concerning our products and services.