COOPER BUSSMANN (EATON‘S)

LPJ系列 Class J 600Vac 慢速熔断器

  • Low-Peak™ LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

  • Low-Peak™ LPJ Class J 600Vac/300Vdc, 70-600A, dual element, time-delay fuses

 

Low-Peak™ LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

 

Catalog symbol :

  • LPJ-(amp)SP (non-indicating)

  • LPJ-(amp)SPI (indicating)

Description::

Bussmann® series Ultimate protection LPJ Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication. Timedelay – 10 seconds (minimum) at 500% of rated current.

 

Specifications: Ratings

Volts

  • 600Vac

  • 300Vdc*

Amps  : 1-60A

IR  :

  • 300kA Vac RMS Sym.

  • 100kA Vdc

* Indicating versions not Vdc rated.

 

Agency information

  • UL® Listed, Guide JDDZ, File E4273

  • CSA® Certified, Class 1422-02, File 53787, Class J per CSA 22.2 No. 248.

  • CE

  • RoHS compliant

 

Catalog numbers (amps) – non-indicating fuses

    LPJ-1SP

    LPJ-3SP

  LPJ-7SP**

  LPJ-25SP**

    LPJ-1-1⁄4SP

    LPJ-3-2⁄10SP

  LPJ-8SP**

  LPJ-30SP**

    LPJ-1-6⁄10SP

    LPJ-3-1⁄2SP

  LPJ-9SP**

  LPJ-35SP**

    LPJ-1-8⁄10SP

    LPJ-4SP

  LPJ-10SP**

  LPJ-40SP**

    LPJ-2SP

    LPJ-4-1⁄2SP

  LPJ-12SP**

  LPJ-45SP**

    LPJ-2-1⁄4SP

    LPJ-5SP

  LPJ-15SP**

  LPJ-50SP**

    LPJ-2-1⁄2SP

    LPJ-5-6⁄10SP

  LPJ-17-1⁄2SP**

  LPJ-60SP**

    LPJ-2-8⁄10SP

    LPJ-6SP**

  LPJ-20SP**

 

* Open fuse indication available by inserting the suffix I,” e.g., LPJ-15SPI. Requires 75Vac minimum voltage. Indicating fuses are not Vdc rated.

 

Carton Quantity

Amp  Rating

Carton Qty.

1-60A

10

 

Features:

  • Industry’s only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application.

  • Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection.

  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses.

  • Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective coordination easy.

  • Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.

  • Current-limitation protects downstream components against damaging thermal and magnetic effects of short-circuit currents.

  • Dual-element fuses have lower resistance than ordinary fuses so they run cooler. They can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.

  • Proper sizing can provide “no damage” Type 2 coordinated protection for NEMA® and IEC® motor controllers.

  • Space-saving package for equipment downsizing.

 

Recommended fuse blocks and holders:

Fuse amps

1-Pole

2-Pole

3-Pole

Modular open   blocks with optional covers

   

0-30

JM60030-1_ 

JM60030-2_

JM60030-3_

35-60

JM60060-1_ 

JM60060-2_

JM60060-3_

“Pyramid” blocks

0-30

 JP60030-3_

CH holders

0-30

CH30J1_ 

CH30J2_

CH30J3_

35-60

CH60J1_ 

CH60J2_

CH60J3_

Safety J™ holders

0-30

 JT60030_   

35-60

 JT60060_   

For additional information on the Class J fuse blocks and holders, see data sheets no. 10289 (modular open blocks), no.1108 (pyramid blocks), no. 2144 (CH) and no. 1152 (Safety J).

 

Fuse reducers for Class J fuses:

Equipment fuse   clips

Desired fuse   (case size)

Catalog no.   (pairs)

60A

30A

J-63

100A

30A

J-13

60A

J-16

200A

60A

J-26+

 Not for bolt-in applications.

 

Current-limiting effects:

Prospective   S.C.C.

Let-through   current

(apparent RMS   symmetrical vs. fuse rating)

15A

30A

60A

1000

1000

1000

1000

3000

1000

1000

1000

5000

1000

1000

1000

10000

1000

1000

2000

15000

1000

1000

2000

20000

1000

1000

2000

25000

1000

1000

2000

30000

1000

1000

2000

35000

1000

1000

2000

40000

1000

2000

3000

50000

1000

2000

3000

60000

1000

2000

3000

80000

1000

2000

3000

100000

1000

2000

4000

150000

1000

2000

4000

200000

2000

3000

4000

250000

2000

3000

5000

300000

2000

3000

5000

 

 

Low-Peak™ LPJ Class J 600Vac/300Vdc, 70-600A, dual element, time-delay fuses

 

Catalog symbols:

  • LPJ-(amp)SP (non-indicating)

  • LPJ-(amp)SPI (indicating)

 

Description:

Bussmann® series Ultimate protection LPJ Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication. Timedelay  10 seconds (minimum) at 500% of rated current.

 

Specifications:

Ratings

Volts :

  • 600Vac

  • 300Vdc*

Amps  : 70-600A

IR

  • 300kA Vac RMS Sym.

  • 100kA Vdc

* Indicating versions not Vdc rated

 

Agency information :

  • UL® Listed, Guide JDDZ, File E4273

  • CSA® Certified, Class 1422-02, File 53787, Class J per CSA C22.2 No. 248.8

  • CE

  • RoHS compliant

 

Catalog numbers (amps) – non-indicating fuses

  LPJ-70SP

  LPJ-125SP

  LPJ-250SP

LPJ-500SP

  LPJ-80SP

  LPJ-150SP

  LPJ-300SP

LPJ-600SP

  LPJ-90SP

  LPJ-175SP

  LPJ-350SP

 

  LPJ-100SP

    LPJ-200SP**

  LPJ-400SP

 

  LPJ-110SP

  LPJ-225SP

  LPJ-450SP

 

*Open fuse indication available on all part numbers by inserting the suffix “I,” e.g., LPJ-90SPI. Requires 75Vac minimum voltage. Indicating fuses are not Vdc rated.

 

Carton Quantity :

Amp  Rating

Carton Qty.

7-200A

5

225-600A

1

 

Features:

  • Industry’s only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application.

  • Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection.

  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses.

  • Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective coordination easy.

  • Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.

  • Current-limitation protects downstream components against damaging thermal and magnetic effects of short-circuit currents.

  • Dual-element fuses have lower resistance than ordinary fuses so they run cooler.

  • Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.

  • Proper sizing can provide “no damage” Type 2 coordinated protection for NEMA® and IEC® motor controllers.

  • Space-saving package for equipment downsizing.

     

Recommended fuse blocks: :

Fuse amps

1-Pole

2-Pole

3-Pole

70-100

 JM60100-1CR

JM60100-2CR

JM60100-3CR

110-200

 JM60200-1CR

JM60200-2CR

JM60200-3CR

225-400

 JM60400-1CR   

JM60400-2CR

JM60400-3CR

450-600

 JM60600-1CR

JM60600-2CR

JM60600-3CR

For additional information on the JM fuse blocks, see product brochure no. 3192

 

Fuse reducers for Class J fuses:

Equipment fuse   clips

Desired fuse   (case size)

Catalog no.   (pairs)

100A

30A

J-13

60A

J-16

200A

60A

J-26+

100A

J-21+

400A

100A

J-41+

200A

J-42+

600A

200A

J-62+

400A

J-64+

 

Current-limiting effects:

Prospective   S.C.C.

Let-through   current

(apparent RMS   symmetrical vs. fuse rating)

100A

200A

400A

600A

1000

1000

1000

1000

1000

3000

2000

2000

3000

3000

5000

2000

3000

5000

5000

10000

2000

4000

6000

8000

15000

3000

4000

7000

9000

20000

3000

4000

7000

10000

25000

3000

5000

8000

10000

30000

3000

5000

8000

11000

35000

4000

5000

9000

12000

40000

4000

6000

9000

12000

50000

4000

6000

10000

13000

60000

4000

6000

11000

14000

80000

5000

7000

12000

15000

100000

5000

8000

12000

17000

150000

6000

9000

14000

19000

200000

6000

9000

16000

21000

250000

7000

10000

17000

23000

300000

7000

11000

18000

24000

 

制造商零件编号:LPJ-*SP
系列:LPJ-SP系列,慢速延时熔断器
电流:1-600A
电压:600Vac (or less); 300Vdc (or less)
分断容量:300KA VAC RMS SYM /100KA VDC
认证:CE. UL.CSA